Laser transurethral resection of the prostate: Safety study of a novel system of photoselective vaporization with high power diode laser in prostates larger than 80mL
To present the feasibility of photoselective vaporization of the prostate (PVP) with of a new diode laser-resection system. Surgical treatment of benign prostatic hyperplasia (BPH) is constantly evolving. Laser techniques are increasingly used in prostates of large size. A prospective study was performed to evaluate operative data and patient outcomes with PVP using high-power diode laser (HPD) and a novel quartz-head fiber with shovel shape in patients with prostate>80mL. Demographic data, operative time, hemoglobin loss, operative results (IPSS, quality of life (QoL), Qmax, post void residue (PVR), IIEF-5 and micturition diary) and complications following Clavien-Dindo classification are described. Thirty-one patients were included in the study. Sixteen (51.6%) were on active antiplatelet treatment and 12 (38.7%) had received anticoagulants before surgery. All cases were followed at least 6mo. No intraoperative or postoperative major complications occurred. Three patients (9.7%) had minor complications according to Clavien-Dindo classification. Twenty-seven (87.1%) were discharged on postoperative day one without catheter. There were significant improvements in IPSS, QoL, Qmax and PVR, both at 3 and 6mo (P<.0001), but sexual function according to IIEF-5 showed no differences. Urgency (any grade) increased at 3mo (48.4%; P=.002) and considerably decreased at 6mo (9.7%; P<.0001). This pilot experience with shovel shape fiber and HPD is encouraging. It shows that laser-resection is a safe procedure, achieving excellent results in terms of IPSS, QoL and Qmax in large prostates even in high-risk patients. Longer follow-up, comparative and randomized controlled studies are needed to widespread these results.
Prostatic Hyperplasia - pathology; Prospective Studies; Humans; Middle Aged; Male; Transurethral Resection of Prostate - adverse effects; Equipment Design; Prostatic Hyperplasia - complications; Blood Loss, Surgical; Prostate - pathology; Lower Urinary Tract Symptoms - etiology; Volatilization; Aged, 80 and over; Laser Therapy - adverse effects; Laser Therapy - methods; Postoperative Complications; Transurethral Resection of Prostate - methods; Organ Size; Treatment Outcome; Transurethral Resection of Prostate - instrumentation; Erectile Dysfunction - etiology; Prostatic Hyperplasia - surgery; Lasers, Semiconductor; Quality of Life; Aged; Laser Therapy - instrumentation; Index Medicus; Photoselective vaporization of the prostate; High power diode laser; Láser-resección transuretral prostática; Benign prostatic hyperplasia; Láser diodo de alta potencia; Vaporización fotoselectiva de la próstata; Hiperplasia prostática benigna; Laser-resection of the prostate
MEDLINE; Medline Complete; MEDLINE with Full Text; PubMed; MEDLINE (Ovid); MEDLINE - Academic